Improve PI0DALITZ model to dynamically work out maximum probability to make it usuable also for eta --> llgamma decays. Model ETA2MUMUGAMMA is pure one-to-one copy of the PI0DALITZ and as such it is removed.
Details
Details
- Reviewers
jback - Commits
- rEVTGENea7551d3aa8d: Improve PI0DALITZ model.
Will attach some test distributions
Diff Detail
Diff Detail
- Repository
- rEVTGEN evtgen
- Lint
Lint Not Applicable - Unit
Tests Not Applicable
Event Timeline
Comment Actions
In following pdf I compare old code and new version for pi0 --> e+e-gamma, eta --> e+e-gamma and eta -- > mu+mu-gamma. In comparison, old code uses artificially increased maximum probability. Nothing changes on the q2 distribution to the point that the two distributions are hard to distinguish.
Comment Actions
Changes look good, Michal. The code is now more general and has excellent agreement with the previous version. Thanks.